Datasheet
Everlight Electronics Co., Ltd. http:\\www.everlight.com Rev 1 Page: 6of 7
Device No:CDPT-090-013 Prepared date: 2007/5/30 Prepared by: zhou hong
PT908-7C-F
Reliability Test Item And Condition
The reliability of products shall be satisfied with items listed below.
Confidence level:90%
LTPD:10%
NO. Item Test Conditions
Test Hours/
Cycles
Sample
Sizes
Failure
Judgement
Criteria
Ac/Re
1 Solder Heat
TEMP:260℃±5℃
10sec 22pcs 0/1
2 Temperature Cycle
H : +100℃ 15mins
5mins
L : -40℃ 15mins
300Cycle 22pcs 0/1
3 Thermal Shock
H :+100℃ 5mins
10secs
L :-10℃ 5mins
300Cycle 22pcs 0/1
4
High Temperature
Storage
TEMP.:+100℃
1000hrs 22pcs 0/1
5
Low Temperature
Storage
TEMP.:-40℃
1000hrs 22pcs 0/1
6 DC Operating Life V
CE
=5V 1000hrs 22pcs 0/1
7
High Temperature/
High Humidity
85℃ / 85% R.H
1000hrs 22pcs
More than
90% of lead
to be covered
by soldering
I
R
≧U×2
Ee≦L×0.8
V
F
≧U×1.2
U:Upper
Specification
Limit
L:Lower
Specification
Limit
0/1