PD204-6C
Reliability Test Item And Condition
The reliability of products shall be satisfied with items listed below.
Confidence level:90%
LTPD:10%
NO. Item Test Conditions Test Hours/
Cycles
Sample
Sizes
Failure
Judgement
Criteria
Ac/Re
1 Solder Heat
TEMP.:260℃± 5℃
10secs 22pcs 0/1
2 Temperature Cycle
H : +100℃ 15mins
5mins
L : -40℃ 15mins
50Cycles 22pcs 0/1
3 Thermal Shock
H :+100℃ 5mins
10secs
L :-10℃ 5mins
50Cycles 22pcs 0/1
4 High Temperature
Storage
TEMP.:+100℃
1000hrs 22pcs 0/1
5 Low Temperature
Storage
TEMP.:-40℃
1000hrs 22pcs 0/1
6 DC Operating Life V
R
=5V 1000hrs 22pcs 0/1
7 High Temperature/
High Humidity
85℃ / 85% R.H
1000hrs 22pcs
I
L
≦L× 0.8
L:Lower
Specification
Limit