Datasheet
Everlight Electronics Co., Ltd. http:\\www.everlight.com Rev: 1 Page: 6 of 7
Device No:CDIR-090-016 Prepared date:2007/4/27 Prepared by: zhouhong
IR908-7C-F
Reliability Test Item And Condition
The reliability of products shall be satisfied with items listed below.
Confidence level:90%
LTPD:10%
NO. Item Test Conditions Test Hours/
Cycles
Sample
Sizes
Failure
Judgement
Criteria
Ac/Re
1 Solder Heat
TEMP.:260℃±5℃
10secs 22pcs 0/1
2 Temperature Cycle
H : +100℃ 15mins
5mins
L : -40℃ 15mins
300Cycles 22pcs 0/1
3 Thermal Shock
H :+100℃ 5mins
10secs
L :-10℃ 5mins
300Cycles 22pcs 0/1
4 High Temperature
Storage
TEMP.:+100℃
1000hrs 22pcs 0/1
5 Low Temperature
Storage
TEMP.:-40℃
1000hrs 22pcs 0/1
6 DC Operating Life I
F
=20mA 1000hrs 22pcs 0/1
7 High Temperature/
High Humidity
85℃ / 85% R.H
1000hrs 22pcs
Ee≦L×0.8
V
F
≦U
U:Upper
Specification
Limit
L:the initial test
value
0/1