95
Section 4 Trouble Shooting
STOP!
IF YOU SEE THIS SCREEN….
OVER-TEMPERATURE SCREEN
An Over Temperature means that the Duty Cycle has been exceeded and the unit is over heated. This can be
caused by:
Welding past the 60% rating of the welder.
Dirty components, failure to service.
Blocked Air Flow.
Damaged/Broken Fans
What to do:
Allow the unit to continue to run. DO NOT TURN OFF!
Inspect unit for lack of air flow on all sides. Air flows in from back and exhausts from both sides and the
front of the welder. Allow 18” of clearance.
When cool, the unit will reset. Allow 5 extra minutes of additional cooling for a safety factor.
Try again.
If unit will not clear the warning after 15 minutes, turn off and back on.