STICK SELECTION
To begin, select the STICK option by scrolling through the left menu array of LEDs. The LED will light and the following screen
will display briefly. Since there is no shielding gas involved with Stick, the unit reminds the user that the electrode has become
live with “OUTPUT ON”.
Section 2 Setup Guide
SETTING UP WELDING PARAMETERS
STICK FUNCTIONS AND PARAMETER SELECTIONS
SELECTION AND ADJUSTMENT OF STICK PARAMETERS
1. Once the process has been selected, use the right or left arrow button to select the desired parameter for adjustment. The
selected parameter on the pinwheel menu will change color and be highlighted and ready for adjustment.
2. Rotate the top right knob to increase or decrease the parameter value.
NOTICE: One pinwheel segment OR square box will always be highlighted. The default highlighted position is the welding Amper-
age. This allows the top knob to control any highlighted parameter value. It is not necessary to return to the default welding Am-
perage position to weld, but it is a good idea to do so. This will allow on-the-fly adjustment of welding Amperage if needed. The
Voltage block segment is not adjustable and is used for a reference for actual Open Circuit Voltage and Arc Voltage only.