Full Product Manual

48
TIG ALUMINUM (AC TIG) SELECTION OF 2T/4T/PEDAL/FINGER OPERATION
1. To select the type of control function, press and release one of the arrow buttons until the control segment of the pinwheel is
highlighted.
2. Press and release the settings button to bring up the 4 way secondary menu to access the control selections.
3. Press and release one of the arrow buttons to highlight the desired type of control.
4. Once the start type has been highlighted, press and release the home button to return to the main pinwheel menu.
NOTICE: When the home setting is pressed, the highlighted segment in the pinwheel will remain in the control segment. To ad-
just the Amperage on-the-fly, use the arrow buttons to toggle and highlight the square block representing the Amps.
Section 2 Setup Guide
SETTING UP WELDING PARAMETERS
AC TIG FUNCTIONS AND PARAMETER SELECTIONS
HELPFUL HINT:
If the pedal control setting is on, up or down slope times are not needed. Up and down slope time are used for 2T and 4T control
settings. Depending upon the program version of your unit, the unit may ignore the slope time input, even if slope is able to be
set. Some program versions may allow setting of slope values and will use these settings in pedal mode. If so, this will make
using the pedal feel sluggish and delay arc stopping. If operating in the Pedal mode, always set up and down slope value to 0.0.