45
TIG ALUMINUM SELECTION
To begin, select the TIG Aluminum option by scrolling through the left menu array of LEDs. The LED will light and the following
screen will display briefly. Pay attention to the shielding gas reminder, and make sure you have the shielding gas connected and
turned on.
Section 2 Setup Guide
SETTING UP WELDING PARAMETERS
AC TIG FUNCTIONS AND PARAMETER SELECTIONS
SELECTION AND ADJUSTMENT OF TIG ALUMINUM PARAMETERS
1. Once the process has been selected, use the right or left arrow button to select the desired parameter for adjustment. The
selected parameter on the pin wheel will change color and be highlighted and ready for adjustment.
2. Rotate the top right knob to increase or decrease the parameter value.
NOTICE: One pinwheel segment OR square box will always be highlighted. The default highlighted position is the welding Amper-
age. This allows the top knob to control any highlighted parameter value. It is not necessary to return to the default welding Am-
perage position to weld, but it is a good idea to do so. This will allow on-the-fly adjustment of welding Amperage if needed.