TIG STEEL/STAINLESS (DC TIG) SELECTION OF 2T/4T/PEDAL/FINGER OPERATION
1. To select the type of control function, press and release either one of the arrow buttons several times until the Control seg-
ment of the pinwheel is highlighted.
2. Press and release the settings button to bring up the 4 way secondary menu to access the control selections.
3. Press and release one of the arrow buttons to highlight the desired type of control.
4. Once the start type has been highlighted, press and release the home button to return to the main pinwheel menu. When the
home setting is pressed, the highlighted segment in the pinwheel will remain in the control segment. To adjust the Amper-
age on-the-fly, use the arrow buttons to toggle back and highlight the default main (square) Amp segment when all adjust-
ments are completed.
NOTICE: If the pedal control setting is used, up or down slope times are not used. Slope times are used for 2T and 4T control
settings. The unit should ignore the slope time input. If slope times were adjustable, this would create a sluggish feel of the
pedal and delay arc termination. If the control function is set to pedal, up/down slope times are set to 0.0 S.
Section 2 Setup Guide
SETTING UP WELDING PARAMETERS
DC TIG FUNCTIONS AND PARAMETER SELECTIONS