Section 2 Setup Guide
SETTING UP WELDING PARAMETERS
BOOT SCREEN MENU
When the unit is turned on, the unit will display a boot screen similar to the one above while it is powering up and determining the
input voltage. All the LEDs should be lit as well. This will take a few seconds, and then it will default to indicate the last used
process in the vertical LED array. The reminder screen will appear briefly before automatically advancing to the pinwheel shaped
parameter menu for the process.
POWERING UP THE WELDER
PROCESS SELECTION
Once the boot screen menu has cleared, use the process selection arrows to toggle up and down to select the desired welding
process. When a new process is selected, the unit will display a reminder screen with information to conrm the welding process
selected. It will also suggest the required welding gas, if any. Each process will have a similar screen to the one below.
NOTICE:
In all processes, the maximum output is limited in 120V mode. In the Power-Set mode, the selection choices for some of the user