User manual
42
Power Loss:
Log: This box should be permanently checked to log all
Power Loss incidents.
Email Notify: Check this box to enable email notification
of this event when power has been restored. This
requires that valid email settings have been entered in
the Network Setting > Email setup screen.
Network Alarm: Check this box to send out a network
alarm to a client PC when power has been restored.
(This feature requires PowerCon software on the client
PC and proper settings for the Alarm Server in the Network Setup menu; see the Alarm Server section for more information.)
NOTE: As alarms and emails cannot be transmitted without power, the log entry is made when power is restored, and the
same applies to all event notifications.
Network Loss:
Log: Check this box to record Network Loss events in the
log.
Buzzer: Check this box to activate the buzzer when the
network connection is lost.
Alarm Output: Click on one of the numbers in the
dropdown box to let the DVR transmit a signal through the
alarm output with the same number, if this event occurs.
Selecting “None” would disable this reaction.
Output Type: If an Alarm Output has been selected
above this setting, this setting will decide how that Output
is transmitted when this event occurs.
Timeout: The alarm output will last for a set period of
time. If this option is selected, a field will appear under this field for setting the period duration. Setting options are
1~150 seconds.
Permanent: The alarm will remain on until the user presses the “Enter” key on the front panel, or resets the alarm
configuration.
Transparent: The alarm output will continue for as long as the event trigger is detected.
Trans+Timeout: The alarm output will continue as long as the event trigger is detected, then it will continue for the set
time period.
Timeout Duration: This period refers to the Timeout output type above and can be from 1 to 150 seconds.
NOTE:
This function only checks the physical connection (link) to the network. Any network behavior that blocks data
connectivity (blocked ports, IP addressing errors, etc.) is not detected by this function.