2.2 LED Indicators
The LED Indicators present real-time information of systematic operation status.
The following table provides description of LED status and their meaning.
LED
Color/Status
Description
Power
Amber On
Power on
10/100M
Link/ ACT
Green On
Link Up
Green Blinking
Data activating
PoE
Amber On
Port is linked to Power Device
Off
No Power Device is connected
1000M
(Port 9-10)
Green On
Link Up
Green Blinking
Data activating
2.3 Hardware Installation
Set the switch on a large flat space with a power socket close by. The flat space
should be clean, smooth, level and sturdy. Make sure there is enough clearance
around the switch to allow attachment of cables, power cord and allow air
circulation. The last, use twisted pair cable to connect this switch to your PC then
user could start to operate the switch.
AC Power Input
Connect the attached power cord to the AC power input connector, the available
AC power input is range from 100-264VAC.
Ethernet cable Request
The wiring cable types are as below.
10 Base-T: 2-pair UTP/STP Cat. 3, 4, 5 cable, EIA/TIA-568 100-ohm (Max. 100m)
100 Base-TX: 2-pair UTP/STP Cat. 5 cable, EIA/TIA-568 100-ohm (Max. 100m)
1000 Base-T: 4-pair UTP/STP Cat. 5 cable, EIA/TIA-568 100-ohm (Max. 100m)
PoE: To delivery power without problem, the Cat 5/5e and Cat 6 cable is