Installation manual

ENR 400 Installation Manual
16 of 81 ENR400_ma_inst_en_rev01
On lower right side of camera setup screen are additional settings for On Screen Display overlay display:
If all settings are done, confirm with OK in CAMERA setup menu.
Minimum settings in GENERAL menu.
Open camera setup menu >CONFIG > SETTING > tab GENERAL:
1. Please double-check, that all recording HDD are entered correctly under LOCATION.
These drives are entered already by factory depending on order (1 to 4 HDD).
2. Check and adjust the other important recording settings:
Automatic Recycle: with activated checkbox the ENR will delete oldest records, if the recording HDD are filled.
Recycle Range: interval (1h to 1 day), how often ENR checks for deleting old records
Keep Video: If activated, the ENR will delete video data after a defined time period. If not activated, the ENR will
use full HDD capacity for achieving max. recording time.
OSD on/off
OSD of date / date adjustment
OSD of time / time adjustment
OSD camera number
OSD camera name
OSD bitrate of single camera
OSD font settings
Apply selection to all listed cameras