a) Loosen the 4 screws from fixe-lens bracket (or vari-focal lens bracket). Remove
the fixe-lens bracket (or vari-focal lens bracket).
b) Adjust the main board bracket right or left 90°, so that the lens can be positioned to
the correct direction.
c) Screw the lens bracket to the lens to fixe it.
7. Now, the IR LEDs are at upper position. It is feasible to change them to the front
position.
a) Loosen 2 screws from left
side of fixe
-
lens bracket
a) Loosen 2 screws from right
side of fixe
-
lens bracket
b) Adjust the main board
bracket right or left 90°
c) Screw the lens
bracket to the lens