User`s manual

56
Serial Port
Check “Enable PTZ” box to enable PTZ function.
1. Address ID: Enter the address ID of the speed dome.
2. Protocol: shows protocol of this speed dome. Selectable from Everfocus, Pelco-D,
Pelco-P, Samsung and Panasonic.
3. Parity: This field is to select the parity level at which you will be connected. You
can choose between None, Odd, or Even parity levels.
4. Baud Rate: The speed used to transmit instructions or information through the
RS485 port. Choose from the following speeds: 2400, 4800, 9600, 19200, 38400,
57600BPS.
5. Freeze Picture: By selecting “ON”, image will stop at the previous position until
the next position is reached. Select “Off” to disable freeze picture function.
6. Auto Resume: Return to previous mode, if no action for a period. Auto Resume is
selectable from OFF, After 30 sec, After 1 M, after 5 M, After 10 M, After 30 M and
After 60 M. After this period of time, speed dome will resume to the mode you set
in “RESUME TO”. By selecting OFF, this function will be disabled.
7. Resume To: Select the mode to resume to. It is selectable from PREV MODE,
POS.1 (H), TOUR1, PAT.1 and AUTOPAN.
8. Power Up Func: It is selectable from Off, PREV MODE, POS.1 (H), TOUR1,
PAT.1, AUTOPAN and Tracking.
9. Auto Flip: Select ON to enable Auto Flip function or select OFF to disable Auto
Flip.