HD Off:
Figure 4-16 Alarm & Event Menu – Event - HD Off
Buzzer Check box to enable buzzer if the hard drive is turned off (disconnected) or becomes
disabled (cannot be detected by the system).
Email Notify Check box to enable email notification when HD is off. Email operation requires that
valid email settings have been entered in the Network Setting/Email setup screen.
Network Alarm Check box to send out a network alarm to client PC. (requires PowerCon software
and setting up Alarm Server in Network Setup menu)
Alarm Output Selection of relay output as event reaction “NONE(not active), “1” ~ “4” for the relay
(in 4 channel version is only 1 relay available).
Output Type Output action when alarm is triggered.
Timeout: Alarm output lasts for the set time duration.
Permanent: Alarm will be continuously active until user presses “Enter
key.
Transparent: Alarm output remains active until event ends.
Trans+Timeout: Alarm output continues until event ends, then lasts for the
set time duration.
Timeout
Duration
The amount of time the buzzer sounds when the HD is off. Duration selectable from 1
to 150 seconds.