User Manual

. ~
:-r. -+
MANUAL IGNITION
The heater may be manually lit by opening the dress guard (see Cleaning) and while holding down
the ignition button, apply a lighted longreach match or taper to the pilot. The ignition button needs
to be held down for 20 seconds to allow the valve to lock in. Close up the dress guard as described
in the cleaning section.
ABNORMAL OPERATION
As the heater heats up or cools down, expansion or contraction takes place and the occasional
'click' may be heard. This is normal, however, continuous metallic noises, grinding sounds, the
smell of gas or any of the symptoms listed on the fault finding chart should be investigated
immediately. Turn the appliance off and disconnect the gas and electrical supplies. If the fault
cannot be fixed or any doubts exist, contact your nearest EVERDURE service agent or contact
Everdure on the telephone number on the front cover of this booklet.
CONTROLS
The heating controls and fan switches are located under a lid situated on the top right hand side of
the heater. Lighting instructions are affixed to the underside of the lid.
FAN AND FAN SWITCH
The two-speed fan is controlled by the fan switch in the control box, and, as indicated on the control
box lid label, the switch has three positions, slow fast and off.
Selection of slow or fast fan speed in conjunction with High, Medium or Low heat settings is
determined by personal choice and/or heating requirements at the time.
LIGHTING INSTRUCTIONS
Open the control box lid, depress and hold down the 'ON/IGNITION/LOW' button. This button
operates the sparker, which in turn ignites the pilot flame and the low setting burner. It is necessary
to hold down the 'ON/IGNITION/LOW' button firmly for at least 20 seconds to allow the gas valve
to 'lock in'. If the burner fails to light, repeat the ignition sequence described above.
Fan Switch
On/Ignition/Low
MediumlHigh
Off
The ON/IGNITION/LOW button and the MEDIUMIHIGH button each have two operating
positions, which provides three heat settings.
Page4