User Manual
76
Assembly, Operation & Maintenance InstructionsAssembly, Operation & Maintenance Instructions
Barbeque
FORCE
TM
FURNACE
TM
Barbeque only LENGTH
(mm)
WIDTH
(mm)
HEIGHT
(mm)
LENGTH
(mm)
WIDTH
(mm)
HEIGHT
(mm)
1170 515 410 1310 515 410
Barbeque and
stand
1170 750 1170 1310 750 1170
Barbeque
FORCE
TM
FURNACE
TM
Barbeque only LENGTH
(ft)
WIDTH
(ft)
HEIGHT
(ft)
LENGTH
(ft)
WIDTH
(ft)
HEIGHT
(ft)
4 1.7 1.3 4.3 1.7 1.3
Barbeque and
stand
4 2.5 4 4.3 2.5 4
GAS CONNECTIONS
BUTANE & PROPANE GAS REQUIREMENTS
Check Gas Type and specications plate on the underside of the RHS servery.
FOR GAS CYLINDER CONNECTION
1. To achieve the optimum performance from your barbeque, an approved gas cylinder/
bottle must be used. The supplied hose and/or regulator must rst be connected to the
barbeque inlet.
2. Do not connect a gas cylinder/ bottle to a barbeque that is not secured in the supplied
stand or on a stable raised surface. The cylinder should be lower than the barbeque, in
a protected place on a stable surface.
3. Before connecting gas supply, take care that all gas control knobs are in the o position.
Once connected, turn the regulator handle to on to turn on the gas supply. Check all
joints are secure.
NOTE: Only one gas cylinder should be stored on the stand at any one time.
LEAK TESTING
1. Make sure the gas control knob is O and turn the cylinder valve On.
2. Check for leaking joints by brushing with solution of half-liquid detergent and half water.
If a leak is present, bubbles will appear (or you may hear a hissing sound). Retightening
connections can generally repair a leaking joint. You must also check the gas hose and
connection at the gas cylinder. If a leak cannot be resolved, do not proceed and turn
the gas cylinder/bottle valve o.
SPECIAL INSTRUCTIONS FOR THE USE OF
REGULATOR AND PROPANE CYLINDER
GAS HOOK-UP: Only the pressure regulator and hose assembly supplied with the grill
should be used. Any replacement pressure regulator and hose assembly must be specied
by the grill manufacturer. This grill is congured for Liquid Propane. Do not use a Natural Gas
supply.
LIQUID PROPANE CYLINDER REQUIREMENTS: (The LP cylinder must be a 20-lb). A
dented or rusty Liquid Propane cylinder may be hazardous and should be checked by your
supplier. Never use a cylinder with a damaged valve. The Liguid Propane cylinder must be
constructed and marked in accordance with the specications for Liquid Propane cylinders
by United States Department of Transportation (DOT) or the National Standard of Canada,
CAN/CSA-B339, Cylinders, Spheres and Tubes for Transportation of Dangerous Goods
Commission. The 20-lb cylinder must have a shut o valve terminating in a valve outlet
specied, as applicable, for connection type QCC1 in the standard for compressed gas
cylinder valve outlet and inlet connection ANSI/CGA-V-1. Storage of an outdoor cooking
gas appliance indoor is permissible only if the cylinder is disconnected and removed from
the outdoor cooking gas appliance. The cylinder system must be arranged for vapor
withdrawal. The cylinder must include a collar to protect the cylinder valve. Manifold
pressure: (operating) 11 inches water column (W.C.), (non-operating) 11.2 inches water
column (W.C.). The Liquid Propane cylinder must be tted with an Overll Protection
Device (OPD). Remove the plastic valve cover from the Liquid Propane cylinder is placed
into the cart.
DO NOT USE NAKED FLAME FOR LOCATING GAS LEAKS.
IF A LEAK PERSISTS CALL AN AUTHORISED GAS FITTER.
APPLIANCE DETAILS
PROPANE
MODEL
DESIGNATION
DESIGNATION
COUNTRIES
BURNERS COUNTRY GAS
CATEGORY
OUTPUT INJECTOR SIZE HOSE
HBG2GUS GRAPHITEE
2
USA/CAN 2740Pa
2*11000 = 22000Btu/Hr
φ0.04in /φ0.95mm
2ft / 600 mm
HBG2MUS MINT
HBG2RUS RED
HBG2OUS ORANGE
HBG2SUS STONE
HBG3GUS GRAPHITE
3
3*9000 = 27000Btu/Hr
*
φ0.04in /φ0.85mm
HBG3MUS MINT
HBG3OUS ORANGE
HBG3SUS
STONE
Air is admitted at the underside of the combustion chamber (two 1.3in/35mm x
0.8in/20mm gaps between the fat tray and the chamber through an oval hole 3in/75mm
x 5.3in/135mm in size). Exhaust gases are emitted around the edge of the plates
(0.2in/6mm gap) and through a 11in/275mm x 1.6in/40mm slot in the rear of the hood.
When using an open grill, aeration also takes place through the slots of the grill. Burner