Use and Care Manual

2
Table of Contents
Table of Contents .......................................................... 2
Performance .................................................................. 2
Safety Information ......................................................... 2
Warranty ......................................................................... 3
Pre-Installation .............................................................. 4
Shallow Well Installation .............................................. 5
Pressure Switch Assembly Instructions ................... 10
Deep Well Installation ................................................. 11
Troubleshooting .......................................................... 17
Performance
SKU HP
GPH of Water @ Total Discharge Pressure of 40 psi
Max. Pressure
0 ft. 10 ft. 20 ft. 30 ft. 40 ft. 50 ft. 60 ft. 70 ft.
1001480251 3/4 612 486 372 360 318 270 210 180 67 psi
1001480255 1 822 696 540 444 420 360 306 276 67 psi
Safety Information
DANGER: Do not pump flammable or explosive liquids
such as oil, gasoline, kerosene, ethanol, etc. Do not use in
the presence of flammable or explosive vapors. Using this
pump with or near flammable liquids can cause an
explosion or fire, resulting in property damage, serious
personal injury, and/or death.
DANGER: ALWAYS disconnect the power to the pump
before servicing.
DANGER: Do not touch the motor housing during
operation. The motor is designed to operate at high
temperatures. Do not disassemble the motor housing.
DANGER: Do not handle the pump or pump motor with
wet hands or when standing on a wet or damp surface, or
in water.
WARNING: Wear safety goggles at all times when
working with pumps.
WARNING: This is a dual voltage 115/230 V pump.
VOLTAGE SELECTOR INSIDE PRESET TO 230V.
For 115V selection, please open the terminal cover and set
the switch to the proper voltage. All wiring should be
performed by a qualified electrician.
WARNING: Protect the electrical cord from sharp
objects, hot surfaces, oil, and chemicals. Avoid kinking the
cord. Do not use damaged or worn cords.
WARNING: Failure to comply with the instruction and
designed operation of this unit may void the warranty.
ATTEMPTING TO USE A DAMAGED PUMP can result in
property damage, serious personal injury, and/or death.
WARNING: The pump should be connected to a
230V/115V GFCI outlet protected with a
10 amp (230V)/20 amp(115V) fuse or circuit breaker.
CAUTION: Know the pump and its applications,
limitations, and potential hazards.
CAUTION: Secure the pump to a solid base.
CAUTION: Periodically inspect the pump and system
components. Disconnect the pump from the power supply
before inspecting.