Instructions / Assembly
Table Of Contents
 6
Installation (continued)
7 
Securing the fan in place
 □ When the fan is in place, apply a generous amount of 
roong compound between the ange and the shingles 
approximately 1 in. inside the perimeter of the ange and 
begin to secure with nails (not included).
 □ When nished, check the installation for leakage with 
water from a garden hose. Do not spray water directly into 
the vent opening.
Suggested Nailing Pattern
8 
Installing the thermostat
WARNING: When cutting or drilling into a wall or ceiling, do 
not damage electrical wiring and other hidden utilities.
 □ Remove the cover from the thermostat box and, using 
screws (not included) to prevent damage to the control, 
attach the mounting plate to a stud.
 □ Leave the back side of the control unobstructed to allow 
free air circulation behind the box.
 □ Wire the unit to the incoming power supply as follows:
 □ Connect one black wire from the thermostat (B) to the 
black wire of the incoming power supply.
 □ Connect the other black wire from the thermostat (B) to 
the black motor wire. 
 □ Connect the white wire from the power supply to the 
white motor wire.
 □ Attach the ground wire from the incoming power supply 
to the ground screw (1) on the thermostat (B).
1
B
Power
Supply
To
Motor










