Securing the fan in place
□ When the fan is in place, apply a generous amount of
roong compound between the ange and the shingles
approximately 1 in. inside the perimeter of the ange and
begin to secure with nails (not included).
□ When nished, check the installation for leakage with
water from a garden hose. Do not spray water directly into
the vent opening.
Suggested Nailing Pattern
8
Installing the thermostat
WARNING: When cutting or drilling into a wall or ceiling, do
not damage electrical wiring and other hidden utilities.
□ Remove the cover from the thermostat box and, using
screws (not included) to prevent damage to the control,
attach the mounting plate to a stud.
□ Leave the back side of the control unobstructed to allow
free air circulation behind the box.
□ Wire the unit to the incoming power supply as follows:
□ Connect one black wire from the thermostat (B) to the
black wire of the incoming power supply.
□ Connect the other black wire from the thermostat (B) to
the black motor wire.
□ Connect the white wire from the power supply to the
white motor wire.
□ Attach the ground wire from the incoming power supply
to the ground screw (1) on the thermostat (B).
1
B
Power
Supply
To
Motor