Installation Guide
1 2 3
1 2 3 4 5
7. Adjust the flush volume of the flush valve
8. Preparing the push button
9
Installation (continued)
A. Half flush volume adjustment: Adjust the half float up and down while pressing the clip. Decrease half
flush volume by moving half float upward and increase half flush volume by moving half float
downward.
B. Full flush volume adjustment 1: Adjust the full float up and down while pressing the clip. Decrease full
flush volume by moving full float upward and increase full flush volume by moving full float downward.
C. Full flush volume adjustment 2: Decrease full flush volume by moving the full adjustor upward and
increase full flush volume by moving full adjustor downward.
A. Close the water tank lid and measure the distance from the flush button (B) to the top of the water
tank lid with a tape measure, and record it as L1.
B. Loosen the lock nut (B1), unscrew the push rod (B2), and remove the positioning plate (B3).
C. Measure the length from the end of push rod (B2) with a tape measure, mark it at the L position
(L = L1-20mm) with a pencil, and cut off the excess with scissors.
D. Replace the push rod (B2) on the button (B) and tighten the lock nut (B1).
E. When L≥100mm, a positioning plate (B3) must be installed on the push rod (B2).The distance
between the position of the positioning plate and the lower end of the push rod is L3 (L3 = 40mm);
when L<100mm, there is no need for the positioning plate (B3).
NOTE: When adjusting the full float, the full adjustor must be set at scale 5. When adjusting full adjustor, the full float must
be set at scale 1.
Full Adjutor
3x magnification
Full
card
Full adjusting
float
3x magnification
Half
card
Half adjusting
float
3x magnification
B
B1
B3
B2
L1
Reserved part
L
L
L=L1-20mm
B3
Pressure
bar end
Note: when L≥100mm, it needs to be equipped with the localizer
when L <100mm, without the localizer
L2
L3
L2=L1-2mm
L3=40mm