User's Manual

2348 Walsh Avenue
Santa Clara, CA 95051
contact@everactive.com
www.everactive.com
In order to run SW tests on a PC confirm which COM port the Silver Glade HW is assigned to. Go to the
device manager. One ‘USB Serial Port’ is for SVG Prog 2.0 and one is for Silver Glade.
Figure 4: Identify the USB Serial Port
In our examples, the COM port for Silver Glade is COM15. Knowing that a user can configure Silver
Glade to perform wireless tests using the options above.
Examples:
Measure transmitted output power on various channels:
python fcc.py -serport COM15 -cw -channels “0, 16, 32, 48, 63” -power 10
Run in frequency hopping mode:
python fcc.py -serport COM15 -freq_hop -power 10
Installation on a motor
Installation on a motor is designed to be fast and easy. On any motor that has sufficient heat
differential between the motor body to ambient room, meeting product specifications, a Silver Glade
unit can be adhered to the motor, either through its magnetic base or attached with an epoxy or glue.
Attaching the energy harvesting puck to Silver Glade using the USB-C port and required cable will be
sufficient to power the Silver Glade unit. The Silver Glade unit can then be paired via the Evergateway.
Figure 5: Silver Glade unit paired with both PV and TEG energy harvesting modules