Owners Manual
TimeFactor User Guide System Menu Tree
48
To assign the switches, first select the TimeFactor parameter or function (the destination) that
you want to externally control (Mix for example) and then select the Aux Switch that you
want to control it with (the source).
To Setup Parameter Destinations
Turn the Encoder knob to select an external control destination. Destinations include the
TimeFactor parameters and functions that can be controlled by one of the Aux Switches. The
choices are:
BYP – Toggle Bypass/Active. (Bypass type selected in BYPASS)
BK + – Increment Bank number switch function.
BK - – Decrement Bank number switch function.
TAP – Tap tempo switch function.
RPT – Repeat function.
P/B – Toggle between Play and Bank Mode.
REC – Looper Record
PLY – Looper Play
STP – Looper Stop
MT – Looper Empty
DIR – Looper Direction
OCT – Looper Octave
KB0…9 – Because of the limited space in the Billboard display, the Parameter
Control Knob names cannot be meaningfully displayed. Instead, for display
purposes, we’ve numbered the knobs from 0 to 9 shown in the image below.
FS1…3 – Alternate Mode (AUX Switches act as Play Switches when the Stompbox
is in Bank Mode, and Bank Switches when the Stompbox is in Play Mode)
PDL – Use AUX Switch to access full value of Preset’s Expression Pedal assignment
while the switch is held
The notion of using an On/Off control source like an Aux Switch to control a variable
parameter bears some explanation. Consider a variable parameter like Dly Mix. You may want
to be able to use a remote switch to instantly change from 100% Delay A to 100% Delay B.