User Manual
H9 User Guide System Mode
37
Push the Left Footswitch again to set the parameter’s maximum value [MAXVAL].
Turn the Knob to adjust the maximum value. The value is displayed while you’re
turning the Knob and times out to display the selected [MAXVAL] when the Knob
is idle.
Remember, the parameters controlled in this mode are system-wide and will
apply to all Presets.
Note: While it is possible to assign more than one external controller to any
parameter, doing so is likely to cause confusion and is not recommended. Keep in
mind that, if you have previously assigned a MIDI CC to a control destination, you
may want to clear the assignment before setting up a new assignment. To clear,
select the destination (parameter) and select the source (MIDI CC) as [---].
To Setup the External Control Source
Press the Right Footswitch to select the external control source field for editing.
There are two ways to select an external control source - Manual Select or Learn
Mode.
For Manual Select simply turn the Knob to choose the MIDI Control Source. The
choices are:
[---] – No patch
[BND] – MIDI Pitch Bend
[C0] – [C99] - MIDI Continuous Controller messages from 0 to 99.
To use the Learn Mode to select the external control source, Press the Right
Footswitch again. “LEARN” is displayed prompting you to send a MIDI message for
automatic Control Source assignment. Press the Right Footswitch again to exit
LEARN mode and revert to manual source selection.
Press the Left and Right Footswitches to toggle between Source and Destination
to make as many assignments as you wish.
The default patch are as follows:
KB0-KB9 are patched to C22-C29. The default patch is unassigned [---] for all
other [RCV.CTL] destinations.
Press the PRESETS button once to back-up one level to MIDI menu.
Press the PRESETS button twice to go to top level System menu.