User Manual
H9 User Guide System Mode
36
Here’s how it works: Press the HOTKNOB button to select [RCV.CTL]. You will see
two fields (split display) with the left side of the display showing the Destination
and the right side showing the Control source. The two fields are delimited by a
decimal point [BYP.BND]. The Left Footswitch LED is flashing (if it’s not, press the
Left Footswitch to select this field) showing this to be the selected field for
editing.
To Setup Destination
Turn the Knob to select an external control destination - the H9 parameter or
function which will be controlled from an external source. The choices are:
[BYP] – BYPass the unit
[PR+] – Increment Preset number
[PR-] – Decrement Preset number
[TAP] – Tap tempo switch function
[PSW] – Toggle or enable the Performance Switch function
[HK] – HOTKNOB patch
[KB0]…[KB9] - Parameter Control Knobs
[ACT] – Active (Enable Effect – unBypass)
[TOG] – Toggle between Active and Bypass
[TUN] – Tuner
Performance Switch [PSW] – The Performance Switch is used for ‘infinite repeat’
with TimeFactor algorithms, ‘rate change’ with ModFactor algorithms, various
functions with PitchFactor algorithms and ‘HotSwitch’ with Space algorithms.
Refer to the specific algorithm doc for detailed descriptions.
Parameter “Knobs” [KB0]-[KN9] - You can use MIDI CC to control up to 10 virtual
“Knobs.” KB0-KB9 correspond to the ten parameters of the currently running
algorithm. For example, if a Preset based on the Dual Delay algorithm is currently
running, KNOB0 corresponds to the “MIX” parameter. If the H9 is running a Preset
based on the Rotary algorithm, KNOB0 corresponds to the “INTENSITY” parameter.
Press the Left Footswitch to select the Destination (left field of the display) and
turn the Knob to select the virtual Knob (parameter) from KB0 to KB9. Press the
Right Footswitch the assign the Control Source (MIDI CC) to the displayed KB.
When a Parameter Control Knob designator is displayed (KB0… KB9), you can map
the MIDI CC values from 0 to 127 to a selected range of parameter values.
Pressing the Left Footswitch with a KB selected will display [MINVAL]. Turn the
Knob to set the minimum value. The value is displayed while you’re turning the
Knob and times out to display the selected [MINVAL] when the Knob is idle.