User Manual

H9 User Guide System Mode
34
After you’ve selected a Parameter Control Knob, you can set two values for the
parameter; a minimum value [MINVAL] and a maximum value [MAXVAL]. Each
time the assigned switch is pressed, the parameter value instantly toggles
between the minimum and maximum value.
When a Parameter Control Knob designator is displayed (KB0… KB9), pressing the
Left Footswitch will display [MINVAL]. Turn the Knob to set the minimum value.
The value is displayed while you’re turning the Knob and times out to display the
selected [MINVAL] when the Knob is idle.
Push the Left Footswitch again to set the parameter’s maximum value [MAXVAL].
Turn the Knob to adjust the maximum value. The value is displayed while you’re
turning the Knob and times out to display the selected [MAXVAL] when the Knob
is idle.
The parameters controlled in this mode are system-wide and will apply to all
Presets. For example, you could assign an Aux Switch to Decay (KB1) with [MIN
VAL] set to 1 sec and [MAX VAL] set to 2 sec. Pressing the switch will toggle
between these two decay values. If another Effect or Preset is chosen, the Aux
Switch will affect the parameter controlled by KB1 for the currently loaded effect.
Note: When a Preset is loaded, the switches assume the MIN VAL for the assigned
parameters. Pressing the switch for the first time after a Preset load, will toggle
the parameter to MAX VAL.
To Setup the External Control Source
Press the Right Footswitch to select one of three Aux Switches. There are two
ways to select the Aux Switch - Manual Select or Learn Mode.
For Manual Select, turn the Knob to choose the Aux Switch. The choices are:
[TIP] - Aux switch jack tip connection
[RNG] - Aux switch jack ring connection
[T+R] - Aux switch jack tip + ring connection
Note: If [EXPTIP] is set to [PEDAL] in [UTILS] only [RNG] is available.
To use the Learn Mode to select the external control source, press the Right
Footswitch again. LEARN” is displayed prompting you to press an Aux Switch for
automatic assignment. Press the Right Footswitch again to exit LEARN mode and
revert to manual source selection.