Troubleshooting guide

Page 94
Air Plenum – Warm Air Plenum
Location:
The warm air plenum carries room air from the convection fan, past the
hot air plenum where it picks up heat. The room air is then delivered
through the heat tubes into the room. See Figure 21 on Page 96.
Purpose:
The warm air plenum is located behind the hot air plenum and is part of
the Heat Exchange System.
Auger Assembly
Location:
The auger is located in the bottom center of the hopper. See Figure 22 on
Page 97.
Purpose:
The auger is the mechanism that transports Corn from the hopper to the
burn grate. The 2 RPM motor located at the back of the auger is controlled
by the Digital Control Board and is cycled on and off at varying rates
depending on the selected Heat Setting. The
ON
time
increases
and the
OFF
time
decreases
when the Heat Setting is advanced to a higher
setting.
Air Inlet Damper
Location:
The Air Intake Tube is located on the rear of all stoves. The 2diameter
tube has a butterfly damper in the tube to control the Combustion Air. See
Figure 20 on Page 95.
Purpose:
The inlet damper is to adjust combustion airflow to match the
characteristics of specific air inlet and chimney configurations and can be
adjusted for different venting configurations.
Clinker Removal System – Coal Rake
Location:
The Coal Rake sits in the upper area of the Burn Pot. See figure 22 on
page 97. See Figure 10 through 13 on Pages 72 through 74 for more
information on dropping the Clinker.
Purpose:
To allow the clinker to be dropped out of the bottom of the Burn pot
without loosing the fire in the pot. The Coal Rake keeps the burning corn
suspended in the top area of the pot, while dropping the clinker.