Troubleshooting guide

Page 71
Data Table
Based on the default 11.5 second Cycle Time. Cycle time equals the ON time & OFF
Time combined.
Heat Level
Selection
Auger ON
(Seconds)
Combustion
Fan Voltage
+/- 3 Volts
Convection Fan
Voltage
+/- 3 Volts
Corn Fuel
(Lbs./Hour)
+/- 10%
Start-Up
Cycle
Off for the first 5
minutes
100 Volts
OFF
NA
1
1.5
90 Volts
83 Volts
1.7 Lbs.
2
2.0
98 Volts
90 Volts
2.25 Lbs.
3
2.5
105 volts
98 Volts
3.1 Lbs
4
3.0
111 volts
103 Volts
3.7 Lbs.
5
3.5
120 volts
120 Volts
4.25 Lbs.
Figure 8
Figure 9
Feed Rate Adjustment
The Default Cycle Time is 11.5
seconds. Please see figure 9 to the left.
The 11.5-second cycle can be changed
to 13 seconds by placing the jumper on
the 2 pins to the right.
Certain fuels (Mainly Corn and Small
Grains) tend to feed faster and may
need to be slowed down. Placing the
jumper on the 2 pins to the right will
give the stove an Optimum Air to Fuel
Ratio.