Troubleshooting guide

Page 65
Pre-Delivery Check – Multi-Fuel Stoves
One of the easiest ways to prevent problems in the field is to inspect the unit before
leaving to install the stove. Offer the customer the option to Pre-Burn the stove for them
to burn off the odors associated with the first burn.
The following checklist is to be used to quickly inspect the stove:
WARNING: Use caution when inspecting electrical connections to prevent contact
with live circuits.
1. Once the unit has been unboxed, check the unit for hidden freight damage.
2. If any painted surfaces are scuffed up use the appropriate touch-up paint to re-
paint the area.
3. Open side doors and inspect all wiring connections.
4. Make sure the Manual packet is inside the stove for the owner of the stove.
Next turn the stove on by pressing the button labeled #2 to make sure all motors and
blowers are running.
a. Both of the blowers come on at line voltage.
Listen for any blower noise or excessive
vibration. After approximately 30 seconds the
Convection blower will shut off.
b. The ON-OFF light comes on and starts
blinking. The Feed Rate/ Heat Advance light
should be at level #1.
c. Five minutes after starting the stove, the auger
will start feeding fuel on level #1. It will
remain on level #1 until it senses the Proof of
Fire switch.
Verify points a through c and then bypass the
Proof of Fire switch to advance the stove into the
program for normal operation.
Once the Proof of Fire Switch has been bypassed
you will see the following:
d. The ON/Off light will quit blinking and stay
ON constantly.
e. The Convection Fan will come on.
f. Slide the Thermostat switch to T-Stat mode.
The ON/OFF light will start blinking again.
Figure 2