Troubleshooting guide

Page 56
Combustion fan
When in doubt Hot-Wire the fan to a direct source of power to see if fan runs using a
cord with a ¼” insulated Male connector and ¼” insulated Female connector.
Igniter
Attention: The control board sends power to the blowers for the first 30 seconds
after turning the stove on and then the convection fan shuts off. At this point the
stove will go into the start-up cycle and the auger feeds pellets for 2 minutes and the
Igniter comes on. The igniter will run at least 5 minutes and/or shut off when the
Proof of Fire switch locks in.
To test an Igniter with an Ohm meter, the reading will be approximately 57 Ohms. If you
get a reading that is significantly different and the igniter does not get hot enough to
ignite pellets, replace the igniter.