Fuel Flow - Pellets
The flow of Pellets through all freestanding St. Croix pellet stoves, follows a path similar
to the one shown in the example below.
Figure 22
Also shown in the diagram above is the Versa grate System, showing the location of the
Shaft/Cage weldment, the Cam, the Spacer, the Shaker Plate and the Grate Weldment.
Note the orientation of the Igniter Tube through the Front of the stove. This greatly
improves the ease of Installation of an igniter, if replacement is needed.
Versa Grate
System