Troubleshooting guide
Page 22
Data Table
The Cycle Time. equals the ON time & OFF Time combined and is based on an 11.5
second Cycle time.
Heat Level
Selection
Auger ON
(Seconds)
Combustion
Fan Voltage
+/- 3 Volts
Convection Fan
Voltage
+/- 3 Volts
Pellet Fuel
(Lbs./Hour)
+/- 10%
Start-Up
Cycle
2 minutes
100 Volts
OFF
NA
1
1.5
90 Volts
83 Volts
1.25 Lbs.
2
2.5
98 Volts
90 Volts
2.00 Lbs.
3
3.5
105 volts
98 Volts
3.15 Lbs
4
4.5
111 volts
103 Volts
3.7 Lbs.
5
5.5
120 volts
120 Volts
4.5 Lbs.
Figure 7
Feed Rate Adjustment
The Default Cycle Time is 11.5
seconds. Please see figure 8 to the left.
The 11.5-second cycle can be changed
to 10 seconds by placing the jumper on
the 2 pins to the left. This should only
be done if the fuel used feeds slowly.
Please read Point 1 “Feed Rates” on
page 12 for more information regarding
“Assessing Performance Quality of
pellets”. Use Caution when switching
to a shorter Cycle Time.
Certain fuels (Mainly Corn and Small
Grains) tend to feed faster and may
need to be slowed down. Placing the
jumper on the 2 pins to the right will
change the Cycle Time to 13.0 seconds.
Figure 8