Troubleshooting guide
Page 23
Ashby Versa Grate Burn System Data Chart
Based on a default Cycle Time of 11.5 seconds.
Cycle time equals the ON time & OFF Time combined.
The following Chart is in reference to burning Pellets in Program 3.
The Voltages shown in the Chart reflect a line voltage of 120 volts. Actual numbers
may vary based on the actual line voltage provided to the control board and the +/-
Tolerance of the Electronic Components used in the Control Board.
The Ashby-P is approved for Wood Pellets and Cherry Pits. Feed rates will vary
from fuel to fuel and from program to program. The above chart is in reference to
burning Pellets in Program 1 which has the highest BTU Rating for Pellets.
Heat Level
Selection
A
uger ON
(Seconds)
Combustion
Fan Voltage
+/- 10%
Convection Fan
Voltage
+/- 10%
Pellets Fuel
(Lbs./Hour)
+/- 10%
Start-Up
Cycle
Off for the first 5
minutes
100 Volts
OFF
NA
1
1.5
90 Volts
90 Volts
1.25 Lbs.
2
2.5
98 Volts
98 Volts
2.00 Lbs.
3
3.5
108 volts
108 volts
3.15 Lbs
4
4.5
115 volts
115 volts
3.7 Lbs.
5
5.5
120 volts
120 volts
4.5 Lbs.