Troubleshooting guide

Page 22
Ashby Multi-Fuel Burn System Data Chart
Based on a default Cycle Time of 11.5 seconds.
Cycle time equals the ON time & OFF Time combined.
The following Chart is in reference to burning Corn in Program 1.
The Voltages shown in the Chart reflect a line voltage of 120 volts. Actual numbers
may vary based on the actual line voltage provided to the control board and the +/-
Tolerance of the Electronic Components used in the Control Board.
Heat Level
Selection
A
uger ON
(Seconds)
Combustion
Fan Voltage
+/- 3 Volts
Convection Fan
Voltage
+/- 3 Volts
Corn Fuel
(Lbs./Hour)
+/- 10%
Start-Up
Cycle
Off for the first 5
minutes
100 Volts
OFF
NA
1
1.5
90 Volts
90 Volts
1.7 Lbs.
2
2.0
98 Volts
98 Volts
2.25 Lbs.
3
2.5
108 volts
108 volts
3.1 Lbs
4
3.0
115 volts
115 volts
3.7 Lbs.
5
3.5
120 volts
120 volts
4.25 Lbs.