Troubleshooting guide
Page 31 - 31 -
Lincoln SCR Data Table
Based on a Cycle Time of 7.5 seconds.
Cycle time equals the ON time & OFF Time combined.
Heat Level
Selection
A
uger ON
(Seconds)
Combustion
Fan Voltage
+/- 10%
Convection Fan
Voltage
+/- 10%
Pellets
(Lbs./Hour)
+/- 10%
Start-Up
Cycle
3 min ON
6 Min OFF
9 Min Level 1
Line Volts
OFF
NA
1
2.5
90 Volts
90 Volts
1.5 Lbs.
2
3.0
100 Volts
100 Volts
2.6 Lbs.
3
3.5
110 volts
110 Volts
3.7 Lbs
4
4.0
116 volts
116 Volts
4.8 Lbs.
5
4.5
120 volts
120 Volts
5.8 Lbs.
The Voltages shown in the Chart reflect a line voltage of 120 volts. Actual numbers
may vary based on the actual line voltage provided to the control board and the +/-
Tolerance of the Electronic Components used in the Control Board.
The Lincoln SCR is approved for Corn, Wheat, Rye, Cherry Pits, Distiller’s Grain
Pellets and Wood Pellets. Feed rates will vary from fuel to fuel and from program to
program. The above chart is in reference to burning Pellets in Program 1 which has
the highest BTU Rating for Pellets.