Troubleshooting guide

Page 16
Pre-Delivery Check – Pellet Stoves with the Versa Grate system
One of the easiest ways to prevent problems in the field is to inspect the unit before leaving to
install the stove. Offer the customer the option of Pre-Burning the stove for them, to burn off the
odors associated with the first burn.
The following checklist is to be used to quickly inspect the stove:
WARNING: Use caution when inspecting electrical connections to prevent contact with
live circuits.
1. Once the unit has been unboxed, check the unit for hidden freight damage.
2. If any painted surfaces are scuffed up use the appropriate touch-up paint to re-paint the
area.
3. Open side doors and inspect all wiring connections.
4. Make sure the Manual packet is inside the stove for the owner of the stove.
Next turn the stove on by pressing the button labeled 2 in Figure 1 to make sure all motors
and blowers are running.
a. Both of the blowers come on at line voltage. Listen
for any blower noise or excessive vibration. After
approximately 30 seconds the Convection blower
will shut off.
b. The ON-OFF light comes on and starts blinking.
The Feed Rate/ Heat Advance light should be at
level #1.
c. The auger comes on and runs for 2 minutes.
d. The Igniter comes on and stays on until the Proof of
Fire switch locks in.
e. The Versa Grate Motor comes on.
f. Five minutes after turning the stove on the auger
will start feeding pellets on level #1. It will remain
on level #1 until it senses the Proof of Fire switch.
Verify points a through f and then bypass the Proof of
Fire switch to advance the stove into the program for
normal operation. Once the Proof of Fire Switch has been
bypassed you will see the following:
g. The ON/Off light will quit blinking and stay on
constantly.
h. The Convection Fan comes on.
i. Slide the Thermostat switch to T-Stat and/or
StartStat mode. The ON/OFF light will start
blinking again.
Figure 1