Troubleshooting guide

Page 14 - 14 -
Rotation Motor Sensor - Adjustment (#2 Switch, see figure 14)
The
Fan/Limit Control must be working correctly before using this Flow Chart
Rotation Motor – Mechanical
The Drum could be jammed due to a foreign object being stuck in the drum,
or in the event of a failed ignition there is enough unburned fuel in the pot to
prevent it from rotating. If this is the problem, unplug the unit and use a
vacuum to clean out the fuel in the pot. To clear a foreign object may require
that the motor be reversed by hand, as shown in figure 16.
Figure 1