Troubleshooting guide

Page 5 - 5 -
overloads during ignition, adjust the Feedrate down or switch Programs until these fuels
ignite without overloading the Pot. The units must be adjusted for unattended use.
The adjustments that need to be made are:
1 – Choosing the correct Program for the fuel used.
2 – Adjusting the Damper (if needed)
3 – Adjusting the Feedrate (if needed)
4 – Adjusting the Draft Fan Voltage (if needed)
5 Adjusting the Heat Level to a lower setting (to prevent the furnace from excessive
ON/OFF cycling). This will also help in maintaining an even temperature in the
home.
Do not assume the unit functions correctly in SmartStat mode without first adjusting
the unit. When burning grain there are many variables and the unit must be fine tuned
correctly before allowing the unit to run unattended.
The Revolution Burn Pot System – Removal and Installation.
Figure 5
The Revolution Burn System can be removed for maintenance or cleaning if
needed, but should only be done if cleaning through the access cover in the
front of the furnace is not sufficient.
The Revolution Burn Pot System – Parts Break Down