Troubleshooting guide
Page 2 - 2 -
SCF – Revolution – Section 1
Control Board
This Control Board offers several advantages as far as
being able to make adjustments to the Feed Rates and the
Combustion Fan Voltages. All adjustments can now be
made from the front of the control board instead of
having to access the back side of the board and change
jumper settings.
There are 4 different Programs on the board to choose
from depending on the choice of fuel (Pellets, Corn
Wheat, Rye, Cherry Pits or Distiller’s Grain Pellets).
They are also to be used to when having difficulty with
poor quality fuel. If a fuel is high in Ash Content for
instance, a program with a
longer Cycle Time should be
used if the pot is overloading.
To change a program several steps must be followed:
1 - The unit must be OFF and cooled down (P.O.F.
Switch must be open)
2 – The Thermostat Slide Switch must be in Manual
Mode.
3 – Press and Hold the Auger Feed Button and at then
press the High and Low Draft Trim Buttons at the same
time. You will see all five LED lights on the Heat Level
Bar light up at the same time.
The programs break down as follows:
Program 1 -
The Cycle Time is 8.5 seconds. This
program will be the default program when the
furnace is first plugged in.
This program is for use with
Pellets, Corn, Wheat, Rye, Cherry Pits & Distillers Grain
Pellets.
(See figure 2, LED Lights flash Once)
Program 2.
The Cycle Time is 7.5 seconds.
This
program is for use with Pellets,
Good Quality Corn
&
Cherry Pits.
(See figure 2, LED Lights flash Twice)
Program 3.
The Cycle Time is 6.5 seconds.
This
program is for use with Pellets & Cherry Pits.
(See figure
2, LED Lights flash Three times)
Program 4
. The Cycle Time is 5.5 seconds. This
program is for use with Pellets & Cherry Pits. (See
figure 2, LED Lights flash Four times)
Figure 1
Figure 2