Troubleshooting guide
Page 100
Convection Fan
Attention: The control board sends power to the Convection blower for the first 30
seconds after turning the stove on and then shuts it off. If in doubt, bypass the Proof
of Fire Switch and wait 5 minutes to check for voltage coming from the control
board. After waiting 5 minutes you should see the ON/OFF light quit blinking and
stay on constant. At that point you should read approximately 80 volts.
When in doubt Hot-Wire the fan to a direct source of power to see if fan runs using a
cord with two ¼” insulated Male connectors.
Combustion Fan
When in doubt Hot-Wire the fan to a direct source of power to see if fan runs using a
cord with a ¼” insulated Male connector and ¼” insulated Female connector.