Baffle Removal
To remove the baffle, lift the back of the
baffle up to clear the inner back of the
Furnace and slide towards the front of the
Furnace. The baffle will slide out of the
keyhole slots and drop down. When
putting the baffle back in the Furnace,
make sure the screws are in the keyhole
slots and the back of the baffle is lifted
up over the inner back to keep the
Baffle locked in place.
Figure 22
5. Exhaust System. Periodic cleaning of the exhaust system is required. Under certain
conditions chimneys may plug up rapidly. Dirty/High moisture content Corn, wheat
rye or distiller’s grain and poor installations require more frequent chimney cleanings.
See Page 20 “Preventing Chimney Fires”. The products of combustion will also
contain small particles of fly ash. The fly ash will collect in the exhaust vent and
restrict the flow of the flue gases. Judge the frequency of cleaning by checking the
amount of ash that accumulates in the elbows or tee’s of the exhaust system. Ask the
dealer for suggested frequency of cleaning, equipment needed and procedures for
cleaning. Check the Exhaust system and Ash Traps at least once every two months
during the heating season.
6. Gaskets. Periodically inspect the condition of the rope gasket around the door,
window and ash door. Replace as needed.
7. Air Filter. Check the Return Air Filters at least once a month and replace when
needed. The size of the filter is 1” x 12” x 25”.