Service manual
- 6 -
Fan/Limit Control - Replacement
Before installing the new Fan/Limit
Control, be sure to remove the Break-
Away tab between the left and right wiring
circuits. See figure 6 to the left. After
replacing the Fan/Limit Control,
remember to adjust the Fan ON and the
Fan OFF settings. Failure to adjust these
settings may cause the Blower to short
cycle.
Figure 6
Feed Rate Adjustment
Figure 7
The Default Cycle Time is 10.0
seconds. Please see figure 7 to the left.
The 10.0-second cycle can be changed
to 8.5 seconds by placing the jumper on
the 2 pins to the Right. This should
only be done if the fuel used feeds
slowly, such as long Pellets or Cherry
Pits.
Use Caution when switching to a
shorter Cycle Time. If the pot
overloads using a shorter Cycle
Time, set the board back to a Longer
Cycle Time.
Certain fuels (Mainly Corn and Small
Grains) tend to feed faster and may
need to be slowed down. Placing the
jumper on the 2 Center Pins will
change the Cycle Time to 11.5 seconds.