Service manual
- 11 -
SCF-050 Data Table
Based on a default Cycle Time of 10.0 seconds.
Cycle time equals the ON time & OFF Time combined.
Heat Level
Selection
Auger ON
(Seconds)
Combustion
Fan Voltage
+/- 10%
Convection Fan
Voltage
+/- 10%
Corn Fuel
(Lbs./Hour)
+/- 10%
Start-Up
Cycle
Off for the first 5
minutes
100 Volts
OFF
NA
1
2.5
90 Volts
120 Volts
2.0 Lbs.
2
3.0
98 Volts
120 Volts
2.75 Lbs.
3
3.5
105 volts
120 Volts
3.5 Lbs
4
4.0
111 volts
120 Volts
4.35 Lbs.
5
4.5
120 volts
120 Volts
5.20 Lbs.
The SCF-050 is approved for Corn, Wheat, Rye, Cherry Pits, Distiller’s Grain
Pellets and Wood Pellets. Feed rates will vary from fuel to fuel. The above chart is in
reference to burning corn.