Service manual

- 1 -
This addendum covers the SCF-050 Multi-Fuel Add-On Furnace heating system.
Please read through Section B of the St Croix Service Manual that covers the
Multi-Fuel Burn System. The design of this furnace is based on the Freestanding
St Croix stoves.
The Electrical Components of this furnace are the same as those shown in section B
with the following exceptions:
1 - This furnace has a different control board.
2 – The Furnace has a 600-800 CFM Convection Blower
3 The Furnace has a Fan/Limit Control, which has a dual function. It controls the
Room Air Blower and also acts as the High Limit Switch to shut the unit down if
temperatures rise above 200 Degrees F. in the Plenum area.
Control Board Features
The Control Board functions slightly differently that the
freestanding stove versions. Please read the following de-
scription of the Control Board.
a. General Operation of the Furnace.
b. Safety Features, to shut the unit down in the
event the sensors detect a problem in the unit.
The Control Board also has Diagnostic Capabilities to
help in diagnosing 3 areas in the furnace. These areas are:
1. High Temperature Limit.
2. Proof of Fire Sensor
3. Vacuum in the Firebox
A closer look at the Control Board to the right in figure 1
will explain how the board works. There are five buttons
labeled 1 through 5, a slide switch labeled 6 and a LED
Light bar with 5 Heat Settings. The LED Light bar is also
used during the Diagnostic process, see page 80 for
more details on Diagnostic Features.
The buttons on the board function as follows: (Refer to
Figure 1. The touch pad buttons are labeled with the
white numbers 1 through 5)
1. The Heat Level button (1) will advance the setting
between level 1 and 5. Once you reach level 5, it will drop
back to level 1. Each level has a LED light to indicate
where the board is set.
Figure 1
The newsletter for Technical and Warranty issues
SCF-050 Service Manual Addendum
1/5/10
Cover Story
SCF-050 Service Manual
Addendum
1
Control Board Features
How is it different from the
stove version?
Pages 1-2
1
2
SCF-050 Troubleshooting
Flow Charts
Pages 3-5
3
Fan/Limit Control
-Replacement
Feed Rate Adjustments
6
Wiring Schematic
Parts Layout
Pages 8-10
7
8
SCF-050 Data Table
11
Inside this issue:
TechNet
Manufactured and Distributed by Even Temp, Inc.

Summary of content (11 pages)