LABEL MIN. MAX. U.M. DEF. USERS TOTAL WORKING HOURS COUNTER
Hr 1 ---- ---- hour ---- total working hours of the user associated to the output K1 (1)
Hr 2 ---- ---- hour ---- total working hours of the user associated to the output K2 (1)
Hr 3 ---- ---- hour ---- total working hours of the user associated to the output K3 (1)
Hr 4 ---- ---- hour ---- total working hours of the user associated to the output K4 (1)
Hr 5 ---- ---- hour ---- total working hours of the user associated to the output K5 (1)
Hr 6 ---- ---- hour ---- total working hours of the user associated to the output K6 (1)
Hr 7 ---- ---- hour ---- total working hours of the user associated to the output K7 (1)
Hr 8 ---- ---- hour ---- total working hours of the user associated to the output K8 (1)
LABEL MIN. MAX. U.M. DEF. OPERATOR MENU PASSWORD
OPEr -999 9999 ---- 0 Operator Menu password (2)
LABEL MIN. MAX. U.M. DEF. COMPRESSORS POWER MANAGER
Po 1 1 15 ---- 10 power of the compressor associated to the output K1
Po 2 1 15 ---- 10 power of the compressor associated to the output K2
Po 3 1 15 ---- 10 power of the compressor associated to the output K3
Po 4 1 15 ---- 10 power of the compressor associated to the output K4
Po 5 1 15 ---- ---- power of the compressor associated to the output K5
Po 6 1 15 ---- ---- power of the compressor associated to the output K6
Po 7 1 15 ---- ---- power of the compressor associated to the output K7
Po 8 1 15 ---- ---- power of the compressor associated to the output K8
LABEL MIN. MAX. U.M. DEF. USER RUNNING WORKING HOURS COUNTER
t r1 ---- ---- hour ---- running working hours of the user associated to the output K1
t r2 ---- ---- hour ---- running working hours of the user associated to the output K2
t r3 ---- ---- hour ---- running working hours of the user associated to the output K3
t r4 ---- ---- hour ---- running working hours of the user associated to the output K4
t r5 ---- ---- hour ---- running working hours of the user associated to the output K5
t r6 ---- ---- hour ---- running working hours of the user associated to the output K6
t r7 ---- ---- hour ---- running working hours of the user associated to the output K7
t r8 ---- ---- hour ---- running working hours of the user associated to the output K8
LABEL MIN. MAX. U.M. DEF. ALARM CODES READING
AlAr ---- ---- ---- ---- alarms code reading
LABEL MIN. MAX. U.M. DEF. PROBES READING
Pb r ---- ---- (3) ---- suction probe reading
Pb F ---- ---- (4) ---- condensing probe reading (5)
LABEL MIN. MAX. U.M. DEF. ANALOG OUTPUT READING
outF 0 100 % ---- analog output reading (5)
LABEL MIN. MAX. U.M. DEF. CONDENSER FANS REGULATOR
F 1 F 6 F 7 (4) 12.00 condenser fans activation setpoint (5)
Notes
the symbol (1) indicates that the parameter is available both to the first and to the second level
the symbol (2) indicates that the parameter is available to the first level only
the symbol (3) indicates that the unit of measure depends from the parameter /5P and from the parameters /A6 and /A7 (the parameters /
5P, /A6 and /A7 belong to the User Menu; see the chapter User Menu on the page 32)
CONFIGURATION PARAMETERS AND DEFAULT VALUES SUMMARIZING TABLE
Operator Menu configuration parameters