LABEL MIN. MAX. U.M. DEF. USERS TOTAL WORKING HOURS COUNTER
Hr 1 ---- ---- hour ---- total working hours of the user associated to the output K1 (1)
Hr 2 ---- ---- hour ---- total working hours of the user associated to the output K2 (1)
Hr 3 ---- ---- hour ---- total working hours of the user associated to the output K3 (1)
Hr 4 ---- ---- hour ---- total working hours of the user associated to the output K4 (1)
Hr 5 ---- ---- hour ---- total working hours of the user associated to the output K5 (1)
Hr 6 ---- ---- hour ---- total working hours of the user associated to the output K6 (1)
Hr 7 ---- ---- hour ---- total working hours of the user associated to the output K7 (1)
Hr 8 ---- ---- hour ---- total working hours of the user associated to the output K8 (1)
LABEL MIN. MAX. U.M. DEF. OPERATOR MENU PASSWORD
OPEr -999 9999 ---- 0 Operator Menu password (2)
LABEL MIN. MAX. U.M. DEF. COMPRESSORS POWER MANAGER
Po 1 1 15 ---- 10 power of the compressor associated to the output K1
Po 2 1 15 ---- 10 power of the compressor associated to the output K2
Po 3 1 15 ---- 10 power of the compressor associated to the output K3
Po 4 1 15 ---- 10 power of the compressor associated to the output K4
Po 5 1 15 ---- ---- power of the compressor associated to the output K5
Po 6 1 15 ---- ---- power of the compressor associated to the output K6
Po 7 1 15 ---- ---- power of the compressor associated to the output K7
Po 8 1 15 ---- ---- power of the compressor associated to the output K8
LABEL MIN. MAX. U.M. DEF. USER RUNNING WORKING HOURS COUNTER
t r1 ---- ---- hour ---- running working hours of the user associated to the output K1
t r2 ---- ---- hour ---- running working hours of the user associated to the output K2
t r3 ---- ---- hour ---- running working hours of the user associated to the output K3
t r4 ---- ---- hour ---- running working hours of the user associated to the output K4
t r5 ---- ---- hour ---- running working hours of the user associated to the output K5
t r6 ---- ---- hour ---- running working hours of the user associated to the output K6
t r7 ---- ---- hour ---- running working hours of the user associated to the output K7
t r8 ---- ---- hour ---- running working hours of the user associated to the output K8
LABEL MIN. MAX. U.M. DEF. ALARM CODES READING
AlAr ---- ---- ---- ---- alarms code reading
LABEL MIN. MAX. U.M. DEF. PROBES READING
Pb r ---- ---- (3) ---- suction probe reading
Pb F ---- ---- (4) ---- condensing probe reading (5)
LABEL MIN. MAX. U.M. DEF. ANALOG OUTPUT READING
outF 0 100 % ---- analog output reading (5)
LABEL MIN. MAX. U.M. DEF. CONDENSER FANS REGULATOR
F 1 F 6 F 7 (4) 12.00 condenser fans activation setpoint (5)
Notes
• the symbol (1) indicates that the parameter is available both to the first and to the second level
• the symbol (2) indicates that the parameter is available to the first level only
• the symbol (3) indicates that the unit of measure depends from the parameter /5P and from the parameters /A6 and /A7 (the parameters /
5P, /A6 and /A7 belong to the User Menu; see the chapter User Menu on the page 32)
CONFIGURATION PARAMETERS AND DEFAULT VALUES SUMMARIZING TABLE
Operator Menu configuration parameters