CONFIGURATION PARAMETERS AND DEFAULT VALUES SUMMARIZING TABLE
Configurator Menu configuration parameters - Operator Menu configuration parameters
CONFIGURATOR MENU CONFIGURATION PARAMETERS
LABEL MIN. MAX. U.M. DEF. USERS TOTAL WORKING HOURS COUNTER
Hr 1 ---- ---- hour ---- total working hours of the user associated to the output K1 (1)
Hr 2 ---- ---- hour ---- total working hours of the user associated to the output K2 (1)
Hr 3 ---- ---- hour ---- total working hours of the user associated to the output K3 (1)
Hr 4 ---- ---- hour ---- total working hours of the user associated to the output K4 (1)
Hr 5 ---- ---- hour ---- total working hours of the user associated to the output K5 (1)
Hr 6 ---- ---- hour ---- total working hours of the user associated to the output K6 (1)
Hr 7 ---- ---- hour ---- total working hours of the user associated to the output K7 (1)
Hr 8 ---- ---- hour ---- total working hours of the user associated to the output K8 (1)
LABEL MIN. MAX. U.M. DEF. OPERATOR MENU PASSWORD
OPEr -999 9999 ---- 0 Operator Menu password (2)
LABEL MIN. MAX. U.M. DEF. USER-RELAY OUTPUT CONFIGURATION
tyP1 undF Cho ---- CP user to associate to the output K1
tyP2 undF Cho ---- CP user to associate to the output K2
tyP3 undF Cho ---- CP user to associate to the output K3
tyP4 undF Cho ---- CP user to associate to the output K4
tyP5 undF Cho ---- FAn user to associate to the output K5
tyP6 undF Cho ---- FAn user to associate to the output K6
tyP7 undF Cho ---- FAn user to associate to the output K7
tyP8 undF Cho ---- FAn user to associate to the output K8
LABEL MIN. MAX. U.M. DEF. COMPRESSORS POWER MANAGER
Po 1 1 15 ---- 10 power of the compressor associated to the output K1
Po 2 1 15 ---- 10 power of the compressor associated to the output K2
Po 3 1 15 ---- 10 power of the compressor associated to the output K3
Po 4 1 15 ---- 10 power of the compressor associated to the output K4
Po 5 1 15 ---- ---- power of the compressor associated to the output K5
Po 6 1 15 ---- ---- power of the compressor associated to the output K6
Po 7 1 15 ---- ---- power of the compressor associated to the output K7
Po 8 1 15 ---- ---- power of the compressor associated to the output K8
Notes
the symbol (1) indicates that the parameter is available both to the first and to the second level
the symbol (2) indicates that the parameter is available to the first level only.
OPERATOR MENU CONFIGURATION PARAMETERS
LABEL MIN. MAX. U.M. DEF. USERS STATUS
St 1 OFF On ---- ---- status of the user associated to the output K1
St 2 OFF On ---- ---- status of the user associated to the output K2
St 3 OFF On ---- ---- status of the user associated to the output K3
St 4 OFF On ---- ---- status of the user associated to the output K4
St 5 OFF On ---- ---- status of the user associated to the output K5
St 6 OFF On ---- ---- status of the user associated to the output K6
St 7 OFF On ---- ---- status of the user associated to the output K7
St 8 OFF On ---- ---- status of the user associated to the output K8