Installation Manual
Safety requirements
Warning: Always perform a visual inspection for damage before starting a
charging session. Check that the contact area of the charging plug is free from dirt
and moisture; check the charging cable for cuts or abrasions to the insulation and
check the charging cable plug of Elvi for rm seat.
Connecting and installing this product must be done by a qualied electrician.
The owner or user is responsible for the installation, operation, and maintenance of
the charging station, whereby both the law regarding the safety of persons, animals
and property must be observed, as well as the installation instructions enforced in the
country of use.
Read the Safety instructions before starting work on the installation of this charging
station.
Warning: Risk of electric shock.
Before installing the wall dock, make sure the power line(s) which are used are
switched off on your service panel.
Warning: The installation settings of your service panel must always be adjusted
by a qualied electrician.
Be aware that local regulations for the installation of charging stations/electric vehicles
supply equipment may be applicable and these may vary depending on your region/
country of residence. The installing party must always ensure that the charging station/
electric vehicle supply equipment is installed according to the local regulations.
Ensure that the correct supply voltage/power and the service panel are properly
secured.
• Before shipment, each EVBox charging station is checked for correct connections
and the charging station is operationally tested.
• Before switching on the charging station, check that the power source available
corresponds to the conguration settings of the product as described in this
manual.
• Ensure that the equipment is used under the correct operating conditions.
• Never operate the product in wet, dusty or explosive surroundings.
• Ensure that there is always adequate space (at least 8”) surrounding the product
for ventilation purposes.
2. install wall dock
Planning the installation
Minimum Requirements
• Review the capacity of the electrical installation and calculate the existing
electrical load in order to determine the maximum allowable operating
current. Take into consideration any applicable local safety margins when
calculating the maximum allowable operating current, in order to prevent
black-out situations
• Calculate the distance between the service panel and charging station and
apply the appropiate wire guage for the calculated distance in order to
ensure minimal voltage drop.
• Obtain any necessary permits from the local authority that has jurisdiction
and conrm that the follow-up inspection is performed by a qualied
electrician after completion of the installation.
• Use only copper conductors.
• Use conductors that are sized in accordance with local wiring regulations.
The selected cable gauge must be able to sustain periods of a constant
load up to 40A.
• The use of protective devices is mandatory. The circuit protection device
chosen must incorporate a suitable residual-current device (RCD) and
overcurrent protection in relation to the electrical load selected.
• The circuit breaker must be in line with the capacity of the charging cable
(3.7, 7.2 kW). If the amperage rating of the charging cable is different than
the amperage rating of the MCB, the installer/user must change the station
settings in the mobile station management application and/or backend
portal as provided by the supplier of this product.
Location
Position the charging station in surroundings not subject to extreme sunlight
conditions, high heat or excessive water exposure. Make sure the charging
station is installed on a location where it is not prone to damage from the outside.
The charging station can be installed on a at and sturdy wall or on the optional
pole to create a free standing installation.Consult EVBox or your distributor for
more details.
2. install wall dock
13 14