Installation Manual
3. technical specications
Item Description
Connection capacity 120 / 240 V AC - 60 Hz
Output power
(via charging cable)
max 32 A, 2-phase installation (3.7 - 7.4 kW)
Temperature range -13 °F to +140 °F (-25 °C to +60 °C) for storage and oper-
ation
Operating humidity Max. 95% - non condensing
Max. Installation height 6560 ft (+2000 m) above sea level
Housing Polycarbonate UL94 V-0
Dimensions (LxWxH) 13 x 7 x 6 in (328 x 186 x 161 mm)
Weight 24.2 lbs (11 kg), 1-phase 32 A station with 25 ft (8 m) cable
Communication protocol OCPP 1.5 S, 1.6 S, 1.6 J
109