Installation Manual

21
6. change charging cable
Warning: Risk of electric shock.
Before changing the charging cable, make sure that the
power line you’re using is switched off on your service
panel. The LED ring of the charging plug must be off.
6.1
Take out the keys from the folder in the box.
Insert the keys into the slots in the bottom of the wall
dock. This releases the snap-t connection of the
charging station to the wall dock. Make sure to push
them in until they only stick out approx. 2” (50 mm) and
cannot be pushed in any further.
Now you can remove your charging station from the
wall dock. Pull the charging station away from the wall
dock in a straight line.
Caution: Do not twist or skew the charging station,
as that might damage the station’s snap ts and/or
connectors.
Be aware that the charging station is still xed on the
connector (socket) of the wall dock and it requires some
force to pull it off.
Caution: Do not use the charging cable for pulling
the station out of the wall dock.
Take out the keys from Elvi wall dock.
6.2
Turn the charging station around and place the front
face of the station on a soft and stable surface.
Untighten the bolt in the back with the supplied Torx
T30 bit and take the bolt out.
6.3
Place the station on its side and unplug the old cable
out of the charging station.
It is best to store the old cable in its original packaging.
Tools you need to change the cable
22
Bit T30
6. change charging cable
6.4
Take the new charging cable out of the box. Check that the
rubber sealing ring on the charging plug is in place and not
twisted. This is to ensure that the proper ingress protection
levels are met (IP54 for EU and NEMA 3R for US).
Place the station on its side and plug the cable into the station.
Make sure you press the charging cable until it is rmly secured.
6.5
Turn the station around and place the front face of the station on
a soft and stable surface.
Insert the bolt and tighten it rmly with the supplied Torx T30 bit.
6.6
Place the station on its side.
Caution: double check that the charging cable plug is
properly secured into the station with the bolt.
6.7
Align the station against the wall dock and the connectors and press it in a straight line until
you hear a clicking sound. To ensure that the connection is fully secured, press rmly on all four
corners and check that there is no air gap between the wall dock and the station.
6.8
When upgrading your charging cable to a version that is suitable for higher power application,
make sure that the applied RCD and MCB in the service panel are in line with local regulations,
and are also adequate for the type of charging cable installed and the amount of power Elvi
can supply (3.7or 7.2 kW).
Check with your installer whether the selected output power from your Elvi can be supported
by your local electrical installation. The setting of your maximum avialable amperage may
need to be adjusted in the mobile station management application and/or backend portal
account as provided by the operator or service provider for this product. For further details,
contact your operator or service provider.
CLICK