User Manual

29
EN
Step 6: Testing and completion
1. Check all plug connections on the controller and communication module by rmly
pressing all connectors into position and ensuring they’re all in the correct spot (matching
color and size).
2. Power up the unit. The charging station will now carry out an automatic test. The LED ring
around the socket will show the following color indications during the test (max. 60 seconds):
Red ashing: Starting up, running test protocol, and establishing a connection to
the network.
Green ashing: Standby, ready for use.
3. Close the covers as shown:
Hang the cover(s) onto the frame by inserting the
top into the edge of the frame and hinging the
cover(s) downwards. For BusinessLine Double
stations, lift up on the charging cable to give the
cover proper clearance.
Make sure that the cover(s) lock into the frame
properly and that the rubber seals are in place in
order to guarantee NEMA-3R protection. Check
also that the cover(s) lock securely into the open
notch at the bottom of the frame.
Note: Do not close the cover until the post-installation
checklist is completed (see page 29).
4. Screw the cover(s) back on using the space under
the unit.
We recommend a mini ratchet to access
tight spaces
5. Test the unit with an electric vehicle or an EVSE tester.