User Manual

27
EN
4. Pull the cables from the top of the unit. The power cables needs to be attached to the
terminal blocks located on either side at the top of the unit. Strip the ends of the power
supply cables, if not done already.
5. Using a screw driver, push the spring clamps to connect the power supply cables to the
power line terminal blocks labeled L1, GND (ground) and L2. The ground (often green or
yellow/green) must be connected to GND, L1 (often brown or black) is connected to terminal
L1, and L2 (often white) is connected to terminal block L2. Repeat for other side of the unit.
4b. Wiring the BusinessLine Double (pole/wall)
1. Insert the power cables through the center cavity.
2. Snake the power cables upwards into the tunnels above the cavity.
3. Continue snaking the power cables from behind the components using the tunnels
(one set of cables per side — two hot and one ground apiece).